Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.954
Filtrar
1.
Echocardiography ; 41(4): e15804, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38578295

RESUMO

A 60-year-old man presented with breathlessness. Nearly four decades previously, he had required three operations for Staphylococcus aureus infective endocarditis of the tricuspid valve and had received a bioprosthetic valve. He had critical tricuspid bioprosthesis stenosis which was treated successfully by valve-in-valve transcatheter tricuspid valve replacement using a balloon-expandable transcatheter heart valve. One year after intervention, the patient is well with no tricuspid valve stenosis or regurgitation.


Assuntos
Bioprótese , Endocardite Bacteriana , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Estenose da Valva Tricúspide , Masculino , Humanos , Pessoa de Meia-Idade , Adulto , Bioprótese/efeitos adversos , Constrição Patológica , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Estenose da Valva Tricúspide/diagnóstico por imagem , Estenose da Valva Tricúspide/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Endocardite Bacteriana/diagnóstico por imagem , Endocardite Bacteriana/cirurgia , Resultado do Tratamento , Desenho de Prótese , Falha de Prótese
2.
J Cardiothorac Surg ; 19(1): 219, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627820

RESUMO

OBJECTIVES: Thrombocytopenia following Perceval aortic valve replacement has been described previously with variable outcome. Studies have lacked a robust analysis of platelet fluctuation and factors affecting it. We aimed to statistically describe the trend in thrombocyte variability as compared with conventional aortic valve replacement, and to assess predictors as well as impact on associated outcomes. METHODS: One hundred consecutive patients with first-time Perceval were retrospectively compared to 219 patients after Perimount Magna Ease valve replacement. The primary outcome was the serial thrombocyte count on day 0-6. Generalized estimating equations were used to analyse the data using fixed-effect models: for the effect of the post-operative day on platelet count, and random-effect models estimating both time-variant (platelets) and time in-variant variables (valve type, age, LV function, pre-op platelet level). RESULTS: Perceval patients were older (72 ± 1 vs 68 ± 1 years, p < 0.01) with higher NYHA status (3(2-3) vs 2(1-2), p < 0.001). Mean platelet count in the sutureless group was lowest on day 2 (91.9 ± 31.6 vs 121.7 ± 53.8 × 103 µl-1), and lower on day 4 (97.9 ± 44) and 6 (110.6 ± 61) compared to the conventional group (157.2 ± 60 and 181.7 ± 79) but did not result in a higher number of transfusions, bleeding or longer hospital stay (p > 0.05). Reduced platelet count was a strong predictor of red cell transfusion in the conventional (p = 0.016), but not in the sutureless group (p = 0.457). Age (Coef -1.025, 95%CI-1.649--0.401, p < 0.001) and CPB-time (Coef 0.186, 95%CI-0.371--0.001, p = 0.048) were predictors for lower platelet levels. CONCLUSION: Considering the older patient profile treated with Perceval, postoperative thrombocytopenia does not impact on outcome in terms of transfusions, complications or hospital stay.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Trombocitopenia , Humanos , Valva Aórtica/cirurgia , Estudos Retrospectivos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Bioprótese/efeitos adversos , Desenho de Prótese , Próteses Valvulares Cardíacas/efeitos adversos , Trombocitopenia/etiologia , Fatores de Risco , Progressão da Doença
3.
J Cardiothorac Surg ; 19(1): 191, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38589959

RESUMO

BACKGROUND: Fungal endocarditis is a rare but serious condition associated with high mortality rates. Various predisposing factors contribute to its occurrence, such as underlying cardiac abnormalities, cardiac surgeries, prosthetic cardiac devices, and central venous catheters. Diagnosing fungal endocarditis, particularly Aspergillus, poses challenges, often complicated by negative blood cultures. CASE PRESENTATION: This report details a case of extensive ascending aorta involvement in Aspergillus endocarditis (AE) in a 24-year-old man with a history of bioprosthesis aortic valve replacement (AVR). Three months post-AVR, he presented with pericardial effusion and aortic rupture, leading to a redo biological valved conduit aortic root replacement (Bentall surgery). Despite the intervention, the tubular graft exhibited extensive Aspergillus involvement, resulting in graft disruption and significant peri-aortic infection. A second redo procedure involving aortic homograft root replacement was performed. Unfortunately, the patient succumbed two days after the surgery. CONCLUSION: A combined approach of medical and surgical therapies is recommended to manage fungal endocarditis. Despite efforts, the mortality rate associated with Aspergillus endocarditis remains unacceptably high, with no significant difference observed between combination therapy and antifungal treatment alone. Further research is essential to explore novel therapeutic strategies and improve outcomes for patients with this challenging condition.


Assuntos
Bioprótese , Endocardite , Doenças das Valvas Cardíacas , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Micoses , Humanos , Masculino , Adulto Jovem , Aorta/cirurgia , Aorta Torácica/cirurgia , Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Endocardite/diagnóstico , Endocardite/cirurgia , Doenças das Valvas Cardíacas/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos
4.
Kyobu Geka ; 77(3): 206-209, 2024 Mar.
Artigo em Japonês | MEDLINE | ID: mdl-38465492

RESUMO

We report a case of bioprosthetic valve dysfunction and acute aortic valve regurgitation. The case was a 75-year-old female who had sudden onset chest pain. ST-segment depression in several leads on electrocardiogram( ECG) suggested acute coronary syndrome. Coronary angiography showed no significant stenosis in coronary arteries. Transesophageal echocardiography revealed severe aortic regurgitation, suggesting that angina was caused by myocardial ischemia associated with acute aortic regurgitation. She was diagnosed as having bioprosthetic valve dysfunction, and underwent redo aortic valve replacement. One leaflet of the bioprosthetic valve was torn along the stent post and caused bioprosthetic valve dysfunction. Failed bioprosthetic valve was removed and replaced by a mechanical valve.


Assuntos
Insuficiência da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Feminino , Humanos , Idoso , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Tórax , Próteses Valvulares Cardíacas/efeitos adversos , Dor no Peito/etiologia , Bioprótese/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos
5.
BMJ Case Rep ; 17(2)2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38395470

RESUMO

The Trifecta tissue valve (Abbott, Illinois, USA) is an externally mounted bovine pericardial aortic valve (AV) prosthesis with adequate haemodynamic performance and better early results than another option. However, concerns have been raised about its durability. Recently, reports have emerged about an increased incidence of early structural valve failure after Trifecta implantation, where leaflet tear(s) with dehiscence along the stent post was the primary mode of early failure. In this article, we present the case of a patient in her 70s, 7 years after AV replacement with a Trifecta valve, who developed progressive dyspnoea. Physical examination revealed signs of chronic severe aortic regurgitation (AR). The initial transthoracic echocardiogram showed severe transvalvular AR, but the aetiology could not be determined. Cardiac computed tomography (CT) revealed a flail non-coronary cusp of the Trifecta bioprosthetic valve without vegetation. After discussion, we concluded that our patient was suitable for valve-in-valve transcatheter aortic valve replacement (ViV TAVR).


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Feminino , Humanos , Animais , Bovinos , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Falha de Prótese , Bioprótese/efeitos adversos , Desenho de Prótese , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia
6.
Eur J Cardiothorac Surg ; 65(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38305431

RESUMO

OBJECTIVES: This nationwide retrospective cohort study assessed the impact of the explanted valve type on reoperative outcomes in aortic valve surgery within the UK over a 23-year period. METHODS: Data were sourced from the National Institute for Cardiovascular Outcomes Research (NICOR) database. All patients undergoing first-time isolated reoperative aortic valve replacement between 1996 and 2019 in the UK were included. Concomitant procedures, homograft implantation or aortic root enlargement were excluded. Propensity score matching was utilized to compare outcomes and risk factors for in-hospital mortality was evaluated through multivariable logistic regression. Final model selection was conducted using Akaike Information Criterion through bootstrapping. The primary end point was in-hospital mortality, and secondary end points included postoperative morbidities. RESULTS: Out of 2371 patients, 24.9% had mechanical and 75% had bioprosthetic valves implanted during the primary procedure. Propensity matched groups of 324 patients each, were compared. In-hospital mortality for mechanical and bioprosthetic valve explants was 7.1% and 5.9%, respectively (P = 0.632). On multivariable logistic regression analysis, valve type was not a risk factor for mortality [odds ratio (OR) 0.62, 95% confidence interval (CI) 0.37-1.05; P = 0.1]. Age (OR 1.03, 95% CI 1.01-1.05; P < 0.05), left ventricular ejection fraction (OR 1.62, 95% CI 1.08-2.42; P < 0.05), creatinine ≥ 200 mg/dl (OR 2.21, 95% CI 1.17-4.04; P < 0.05) and endocarditis (OR 2.66, 95% CI 1.71-4.14; P < 0.05) emerged as risk factors for mortality. CONCLUSIONS: The type of valve initially implanted (mechanical or bioprosthetic) did not determine mortality. Instead, age, left ventricular ejection fraction, renal impairment and endocarditis were significant risk factors for in-hospital mortality.


Assuntos
Bioprótese , Endocardite , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Humanos , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Estudos Retrospectivos , Volume Sistólico , Função Ventricular Esquerda , Próteses Valvulares Cardíacas/efeitos adversos , Reoperação , Endocardite/cirurgia , Reino Unido/epidemiologia , Bioprótese/efeitos adversos , Resultado do Tratamento
7.
J Cardiothorac Surg ; 19(1): 95, 2024 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-38355617

RESUMO

BACKGROUND: Rapid-deployment aortic valve replacement (RDAVR) is an alternative to conventional AVR (cAVR) for aortic stenosis. Benefits include a reduction in operative times, facilitation of minimal access surgery and superior haemodynamics compared to conventional valves. However, further evidence is required to inform guidelines, preferably in the form of propensity-matched studies that include mid-term follow-up data. METHODS: This was a single-centre, retrospective, propensity-matched cohort study comparing the Perceval and conventional Perimount Magna Ease valve for short- and mid-term clinical parameters and size-matched mid-term echocardiographic parameters (n = 102 in both groups) from 2014 to 2020. Data were extracted from a nationally managed dataset. RESULTS: There were no demographic differences between the matched groups. The Perceval group had shorter cross-clamp time (Perceval 62 [49-81] minutes; Perimount 79 [63-102] minutes, P < 0.001), shorter bypass time (Perceval 89 [74-114] minutes; Perimount 104 [84-137] minutes, P < 0.001), and more frequent minimally-invasive approaches (Perceval 28%; Perimount 5%, P < 0.001). Size-matched haemodynamics showed initially higher gradients in the Perceval group, but haemodynamics equalised at 12 + months. The Perceval group had a more favourable % change in the left ventricular posterior wall dimension at 2 + years (Perceval - 4.8 ± 18; Perimount 17 ± 2). CONCLUSIONS: The Perceval facilitated shorter operations, which may benefit intermediate-high-risk, elderly patients with comorbidities requiring concomitant procedures. It also facilitated minimally invasive surgery. Size-matched haemodynamic performance was similar at mid-term follow-up, with the Perceval possibly better facilitating regression of left ventricular hypertrophy.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Humanos , Idoso , Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Estudos Retrospectivos , Estudos de Coortes , Implante de Prótese de Valva Cardíaca/métodos , Resultado do Tratamento , Desenho de Prótese , Próteses Valvulares Cardíacas/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia
8.
Eur J Cardiothorac Surg ; 65(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38331412

RESUMO

OBJECTIVES: While current data show a clear trend towards the use of bioprosthetic valves during aortic valve replacement (AVR), durability of bioprosthetic valves remains the most important concern. We conducted a 1st systematic review of all available evidence that analysed early and mid-term outcomes after AVR using the Inspiris RESILIA™ bioprosthesis. METHODS: A systematic literature search was performed to identify all relevant studies evaluating early and mid-term outcomes after AVR using the Inspiris RESILIA bioprosthesis and including at least 20 patients with no restriction on the publication date. Subgroup meta-analysis was performed to compare Inspiris RESILIA and PERIMOUNT Magna Ease bioprosthesis and to pool the early postoperative mortality and stroke rates. RESULTS: A total of 416 studies were identified, of which 15 studies met the eligibility criteria. The studies included a total of 3202 patients with an average follow-up of up to 5.3 years. The average age of patients across the studies was 52.2-75.1 years. Isolated AVR was performed in 39.0-86.4% of patients. In-hospital or 30-day postoperative mortality was 0-2.8%. At the mid-term follow-up, freedom from all-cause mortality was up to 85.4%. Among studies with mid-term follow-up, trace/mild paravalvular leak was detected in 0-3.0%, while major paravalvular leak was found only in up to 2.0% of patients. No statistically significant differences in terms of mortality (P = 0.98, odds ratio 1.02, 95% confidence interval 0.36-2.83) and stroke (P = 0.98, odds ratio 1.01, 95% confidence interval 0.38-2.73) between the Inspiris RESILIA bioprosthesis and PERIMOUNT Magna Ease bioprosthesis were observed in the subgroup meta-analysis. CONCLUSIONS: Mid-term data on the safety and haemodynamic performance of the novel aortic bioprosthesis are encouraging. Further comparative studies with other bioprostheses and longer follow-up are still required to endorse durability and safety of the novel bioprosthesis.


Assuntos
Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Humanos , Pessoa de Meia-Idade , Idoso , Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Desenho de Prótese , Resultado do Tratamento , Estudos Retrospectivos
9.
Am J Cardiol ; 215: 1-7, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38232811

RESUMO

Structural valve degeneration is increasingly seen given the higher rates of bioprosthetic heart valve use for surgical and transcatheter aortic valve replacement (TAVR). Valve-in-valve TAVR (VIV-TAVR) is an attractive alternate for patients who are otherwise at high risk for reoperative surgery. We compared patients who underwent VIV-TAVR and native valve TAVR through a retrospective analysis of our institutional transcatheter valve therapy (TVT) database from 2013 to 2022. Patients who underwent either a native valve TAVR or VIV-TAVR were included. VIV-TAVR was defined as TAVR in patients who underwent a previous surgical aortic valve replacement. Kaplan-Meier survival analysis was used to obtain survival estimates. A Cox proportional hazards regression model was used for the multivariable analysis of mortality. A total of 3,532 patients underwent TAVR, of whom 198 (5.6%) underwent VIV-TAVR. Patients in the VIV-TAVR cohort were younger than patients who underwent native valve TAVR (79.5 vs 84 years, p <0.001), with comparable number of women and a higher Society of Thoracic Surgeons risk score (6.28 vs 4.46, p <0.001). The VIV-TAVR cohort had a higher incidence of major vascular complications (2.5% vs 0.8%, p = 0.008) but lower incidence of permanent pacemaker placement (2.5% vs 8.1%, p = 0.004). The incidence of stroke was comparable between the groups (VIV-TAVR 2.5% vs native TAVR 2.4%, p = 0.911). The 30-day readmission rates (VIV-TAVR 7.1% vs native TAVR 9%, p = 0.348), as well as in-hospital (VIV-TAVR 2% vs native TAVR 1.4%, p = 0.46), and overall (VIV-TAVR 26.3% vs native TAVR 30.8%, p = 0.18) mortality at a follow-up of 1.8 years (0.83 to 3.5) were comparable between the groups. The survival estimates were also comparable between the groups (log-rank p = 0.27). On multivariable Cox regression analysis, VIV-TAVR was associated with decreased hazards of death (hazard ratio 0.68 [0.5 to 0.9], p = 0.02). In conclusion, VIV-TAVR is a feasible and safe strategy for high-risk patients with bioprosthetic valve failure. There may be potentially higher short-term morbidity with VIV-TAVR, with no overt impact on survival.


Assuntos
Bioprótese , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estudos Retrospectivos , Falha de Prótese , Resultado do Tratamento , Bioprótese/efeitos adversos , Desenho de Prótese
10.
Eur J Cardiothorac Surg ; 65(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38244569

RESUMO

Bioprosthetic valve dysfunction (BVD) is typically a progressive process related to natural wear of the prosthesis. With acute presentations, possible durability issues or iatrogenic causes need to be considered. Here, we present 2 patients with acute BVD of self-expanding, transcatheter aortic valve replacement post-heart catheterization. The presentations and outcomes, in otherwise normally functioning valves antecedent to the heart catheterizations, raise the question of the increased complexity of coronary access in this valve platform, and whether that or other features provide for greater risk of such events. We believe this to be the first publication of such events and they help to highlight the importance of valve implantation planning, as well as familiarity with the potential complexity of coronary access during heart catheterization.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Resultado do Tratamento , Fatores de Risco , Desenho de Prótese , Cateterismo Cardíaco/efeitos adversos , Bioprótese/efeitos adversos , Doença Iatrogênica , Estenose da Valva Aórtica/cirurgia , Falha de Prótese
11.
Gen Thorac Cardiovasc Surg ; 72(2): 95-103, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37414971

RESUMO

BACKGROUND: The ideal conduit for mitral valve replacement (MVR) remains elusive, particularly among younger patients due to increased life expectancy. We perform a pairwise meta-analysis comparing the use of bioprosthetic valves (BPV) and mechanical mitral valves (MMV) in patients < 70 years old undergoing MVR. METHODS: We comprehensively searched medical databases to identify studies comparing the use of BPV and MMV in patients < 70 years old undergoing MVR. Pairwise meta-analysis was performed using the Mantel-Haenszel method in R version 4.0.2. Outcomes were pooled using the random effect model as risk ratios (RR) with their 95% confidence intervals (95% CI). RESULTS: 16,879 patients from 15 studies were pooled. Compared to MMV, BPV was associated with significantly higher rates of 30-day mortality (RR 1.53, p = 0.0006) but no difference in 30-day stroke (RR 0.70, p = 0.43). At a weighted mean follow-up duration of 14.1 years, BPV was associated with higher rates of long-term mortality (RR 1.28, p = 0.0054). No difference was seen between the two groups for risk of long-term stroke (RR 0.92, p = 0.67), reoperation(RR 1.72, p = 0.12), or major-bleeding (RR 0.57, p = 0.10) at a weighted mean follow-up duration of 11.7, 11.3, and 11.9 years, respectively. CONCLUSION: The use of MMV in patients < 70 undergoing MVR is associated with lower rates of 30-day/long-term mortality compared to BPV. No significant differences were observed for risk of 30-day/long-term stroke, long-term reoperation, and long-term major bleeding. These findings support the use of MMV in younger patients, although prospective, randomized trials are still needed.


Assuntos
Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Humanos , Idoso , Valva Mitral/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Estudos Prospectivos , Acidente Vascular Cerebral/etiologia , Hemorragia/etiologia , Reoperação , Bioprótese/efeitos adversos , Resultado do Tratamento , Valva Aórtica/cirurgia
12.
Heart ; 110(4): 299-305, 2024 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-37643771

RESUMO

OBJECTIVES: Lipoprotein(a) (Lp(a)) is associated with an increased incidence of native aortic stenosis, which shares similar pathological mechanisms with bioprosthetic aortic valve (bAV) degeneration. However, evidence regarding the role of Lp(a) concentrations in bAV degeneration is lacking. This study aims to evaluate the association between Lp(a) concentrations and bAV degeneration. METHODS: In this retrospective multicentre study, patients who underwent a bAV replacement between 1 January 2010 and 31 December 2020 and had a Lp(a) measurement were included. Echocardiography follow-up was performed to determine the presence of bioprosthetic valve degeneration, which was defined as an increase >10 mm Hg in mean gradient from baseline with concomitant decrease in effective orifice area and Doppler Velocity Index, or new moderate/severe prosthetic regurgitation. Levels of Lp(a) were compared between patients with and without degeneration and Cox regression analysis was performed to investigate the association between Lp(a) levels and bioprosthetic valve degeneration. RESULTS: In total, 210 cases were included (mean age 74.1±9.4 years, 72.4% males). Median time between baseline and follow-up echocardiography was 4.4 (IQR 3.7) years. Bioprostheses degeneration was observed in 33 (15.7%) patients at follow-up. Median serum levels of Lp(a) were significantly higher in patients affected by degeneration versus non-affected cases: 50.0 (IQR 72.0) vs 15.6 (IQR 48.6) mg/dL, p=0.002. In the regression analysis, high Lp(a) levels (≥30 mg/dL) were associated with degeneration both in a univariable analysis (HR 3.6, 95% CI 1.7 to 7.6, p=0.001) and multivariable analysis adjusted by other risk factors for bioprostheses degeneration (HR 4.4, 95% CI 1.9 to 10.4, p=0.001). CONCLUSIONS: High serum Lp(a) is associated with bAV degeneration. Prospective studies are needed to confirm these findings and to investigate whether lowering Lp(a) levels could slow bioprostheses degradation.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Feminino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Valva Aórtica/patologia , Lipoproteína(a) , Estenose da Valva Aórtica/complicações , Ecocardiografia , Insuficiência da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Bioprótese/efeitos adversos , Resultado do Tratamento
13.
Eur J Cardiothorac Surg ; 65(1)2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-37756697

RESUMO

OBJECTIVES: This population-based cohort study investigated mid-term outcome after surgical aortic valve replacement with a bioprosthetic or mechanical valve prosthesis in patients aged <50 years in a European social welfare state. METHODS: We analysed patient data from the main social insurance carriers in Austria (2010-2020). Subsequent patient-level record linkage with national health data provided patient characteristics and clinical outcome. Survival, reoperation, myocardial infarction, heart failure, embolic stroke or intracerebral haemorrhage, bleeding other than intracerebral haemorrhage and major adverse cardiac events were evaluated as outcomes. RESULTS: A total of 991 patients were analysed. Regarding demographics, no major differences between groups were observed. Multivariable Cox regression revealed no significant difference in overall survival (P = 0.352) with a median follow-up time of 6.2 years. Reoperation-free survival was decreased (hazard ratio = 1.560 [95% CI: 1.076-2.262], P = 0.019) and the risk for reoperation was increased (hazard ratio = 2.770 [95% CI: 1.402-5.472], P = 0.003) in patients who received bioprostheses. Estimated probability of death after reoperation was 0.23 (CL: 0.08-0.35) after 2 years and 0.34 (CL: 0.06-0.53) after 10 years over both groups. Regarding further outcomes, no significant differences between the two groups were observed. CONCLUSIONS: In patients below 50 years of age receiving aortic valve replacement, implantation of bioprostheses when compared to mechanical heart valve prostheses was associated with a significantly higher rate of reoperations and reduced reoperation-free survival. Nevertheless, we could not observe a difference in overall survival. However, long-term follow-up has to evaluate that a significantly lower rate of reoperations may translate in consistently improved long-term survival.


Assuntos
Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Humanos , Pessoa de Meia-Idade , Próteses Valvulares Cardíacas/efeitos adversos , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Estudos de Coortes , Desenho de Prótese , Reoperação , Bioprótese/efeitos adversos , Hemorragia Cerebral/etiologia , Pontuação de Propensão , Resultado do Tratamento , Estudos Retrospectivos , Falha de Prótese
17.
Can J Cardiol ; 40(2): 300-312, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38072363

RESUMO

With the expansion of transcatheter aortic valve replacement (TAVR) to younger and lower-surgical-risk patients, many younger and less comorbid patients will be treated with TAVR and are expected to have a life expectancy that will exceed the durability of their transcatheter heart valve. Consequently, the number of patients requiring reintervention will undoubtedly increase in the near future. Redo-TAVR and TAVR explantation followed by surgical aortic valve replacement are the different therapeutic options in the event of bioprosthetic valve failure and the need for reintervention. Patients often anticipate being able to benefit from a redo-TAVR in the event of bioprosthetic valve failure after TAVR, despite the lack of long-term data and the risk of unfavourable anatomy. Our understanding of the feasibility of redo-TAVR is constantly improving thanks to bench test studies and growing worldwide experience. However, much remains unknown. In clinical practice, one of the heart team's objectives is to anticipate the need to reaccess the coronary arteries and implant a second or even a third valve when life expectancy may exceed the durability of the transcatheter heart valve. In this review, we address key definitions in the diagnosis of structural valve deterioration and bioprosthetic valve failure, as well as patient selection and procedural planning for redo-TAVR to reduce periprocedural risk, optimise hemodynamic performance, and maintain coronary access. We describe the bench testing and literature in the redo-TAVR and TAVR explantation fields.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Fatores de Risco , Bioprótese/efeitos adversos , Desenho de Prótese
18.
J Am Heart Assoc ; 13(1): e031387, 2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-38156596

RESUMO

BACKGROUND: Whether a bovine or porcine aortic valve bioprosthesis carries a higher risk of endocarditis after aortic valve replacement is unknown. The aim of this study was to compare the risk of prosthetic endocarditis in patients undergoing aortic valve replacement with a bovine versus porcine bioprosthesis. METHODS AND RESULTS: This nationwide, population-based cohort study included all patients who underwent surgical aortic valve replacement with a bovine or porcine bioprosthesis in Sweden from 1997 to 2018. Regression standardization was used to account for intergroup differences. The primary outcome was prosthetic valve endocarditis, and the secondary outcomes were all-cause mortality and early prosthetic valve endocarditis. During a maximum follow-up time of 22 years, we included 21 022 patients, 16 603 with a bovine valve prosthesis and 4419 with a porcine valve prosthesis. The mean age was 73 years, and 61% of the patients were men. In total, 910 patients were hospitalized for infective endocarditis: 690 (4.2%) in the bovine group and 220 (5.0%) in the porcine group. The adjusted cumulative incidence of prosthetic valve endocarditis at 15 years was 9.5% (95% CI, 6.2%-14.4%) in the bovine group and 2.8% (95% CI, 1.4%-5.6%) in the porcine group. The absolute risk difference between the groups at 15 years was 6.7% (95% CI, 0.8%-12.5%). CONCLUSIONS: The risk of endocarditis was higher in patients who received a bovine compared with a porcine valve prosthesis after surgical aortic valve replacement. This association should be considered in patients undergoing both surgical and transcatheter aortic valve replacement.


Assuntos
Bioprótese , Endocardite Bacteriana , Endocardite , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Masculino , Humanos , Animais , Bovinos , Suínos , Idoso , Feminino , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Bioprótese/efeitos adversos , Endocardite Bacteriana/cirurgia , Estudos de Coortes , Endocardite/epidemiologia , Endocardite/etiologia , Implante de Prótese de Valva Cardíaca/métodos
19.
Artigo em Inglês | MEDLINE | ID: mdl-37929628

RESUMO

We present a case of a Staphylococcus epidermidis early prosthetic valve endocarditis after minimally invasive sutureless aortic valve replacement. The patient developed a root abscess with a fistula, severe mitral and periprosthetic regurgitations, with a large mitral vegetation and a residual patent foramen ovale. The surgical approach consisted of a redo median sternotomy, explantation of a sutureless aortic prosthesis, resection of an intervalvular fibrosa and anterior mitral leaflet and debridement of an aortic root-left ventricle outflow tract abscess. These procedures were followed by a root-commando procedure with mitral and aortic root placement using a self-assembled mechanical aortic root conduit. The technique used is an alternative to a root-commando procedure performed with an allograft or a Medtronic Freestyle bioprosthesis. The same technique can be utilized with a commercially available stented bioprosthesis.


Assuntos
Bioprótese , Endocardite Bacteriana , Endocardite , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Humanos , Endocardite Bacteriana/etiologia , Endocardite Bacteriana/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Abscesso/cirurgia , Aorta Torácica/cirurgia , Endocardite/etiologia , Endocardite/cirurgia , Bioprótese/efeitos adversos
20.
Braz J Cardiovasc Surg ; 39(1): e20230111, 2023 10 27.
Artigo em Inglês | MEDLINE | ID: mdl-37889214

RESUMO

INTRODUCTION: Systemic inflammatory response syndrome (SIRS) is related to increased circulating endothelial microparticles (EMP). OBJECTIVE: The aim of this study was to compare the plasma concentration of EMP between patients undergoing aortic valve replacement with conventional bioprosthesis implantation and Perceval™ S (LivaNova) and to evaluate its impact on the inflammatory response in the short-term follow-up. METHODS: This is a randomized clinical trial with 24 patients submitted to isolated aortic valve replacement divided into two groups: Perceval™ S (Group P) and conventional bioprostheses (Group C). Incidence of severe SIRS (three or more criteria) in the first 48 hours postoperatively, EMP release profile, interleukins (IL) 6 and 8, C-reactive protein, and procalcitonin were analyzed preand postoperatively at 24 hours and three months. RESULTS: There were 24 patients (12 in each group), mean age was 69.92±5.17 years, 83.33% were female, the incidence of severe SIRS was 66.7% and 50% in groups C and P, respectively (P=0.68), and EMP showed a significant increase in the 24-hour postoperative period (P≤0.001) and subsequent decrease in the three-month postoperative period (P≤0.001), returning to baseline levels. For IL-6 and IL-8, there was a greater increase in group C at 24 hours postoperatively (P=.0.02 and P<0.001). CONCLUSION: The incidence of severe SIRS was similar in both groups, with significantly higher levels of IL-6 and IL-8, at the 24-hour postoperative period, in group C, however with higher levels of EMP in group P, and subsequent return to baseline levels at the three-month postoperative period in both groups.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Interleucina-6 , Interleucina-8 , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Bioprótese/efeitos adversos , Desenho de Prótese , Síndrome de Resposta Inflamatória Sistêmica/etiologia , Resultado do Tratamento , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...